T
T
T
Treesearch

Assessment of modification factors for a row of bolts or timber connectors

Informally Refereed
Download (PDF 345 KB): https://research.fs.usda.gov/download/treesearch/21036.pdf

Abstract

When bolts or timber connectors are used in a row, with load applied parallel to the row, load will be unequally distributed among the fasteners. This study assessed methods of predicting this unequal load distribution, looked at how joint variables can affect the distribution, and compared the predictions with data existing in the literature. Presently used design procedures were also assessed. The analytical methods were found to predict proportional limit loads but not joint strength.

Citation

Wilkinson, Thomas Lee. 1980. Assessment of modification factors for a row of bolts or timber connectors. Res. Pap. FPL-RP-376. Madison, WI: U.S. Department of Agriculture, Forest Service, Forest Products Laboratory. 24 pages