Decay detection in red oak trees using a combination of visual inspection, acoustic testing, and resistance microdrilling

Informally Refereed
Download (PDF 136 KB): https://research.fs.usda.gov/download/treesearch/32704.pdf

Abstract

Arborists are often challenged to identify internal structural defects hidden from view within tree trunks. This article reports the results of a study using a trunk inspection protocol combining visual observation, single-path stress wave testing, acoustic tomography, and resistance microdrilling to detect internal defects. Two century-old red oak (Quercus rubra) trees located in Capitol Park, Madison, Wisconsin, U.S., were visually inspected and then evaluated using a single-path stress wave timer, an acoustic tomography, and a resistance measuring drill. The trees were subsequently felled, and a disk at each test location was obtained and examined. It was found that the visual inspection and single-path stress wave tests correctly identified a general problem but without specificity; the tomograph accurately revealed the general location and magnitude of the defect within the cross-sections tested but required resistance microdrilling to precisely locate defects and differentiate between decay and crack-induced acoustic shadows.

Citation

Wang, Xiping; Allison, R. Bruce. 2008. Decay detection in red oak trees using a combination of visual inspection, acoustic testing, and resistance microdrilling. Arboriculture & urban forestry. Vol. 34, no. 1 (Jan. 2008): Pages 1-4.