T
T
T
Treesearch

1988 Revisions to the 1978 National Fire-Danger Rating System

Informally Refereed
Download (PDF 1.69 MB): https://research.fs.usda.gov/download/treesearch/593.pdf

Abstract

The 1978 National Fire-Danger Rating System does not work well in the humid environment of the Eastern United States. System modifications to correct problems and their operational impact on System users are described. A new set of 20 fuel models is defined and compared graphically with the 1978 fuel models. Technical documentation of System changes is provided.

Citation

Burgan, Robert E. 1988. 1988 Revisions to the 1978 National Fire-Danger Rating System. Res. Pap. SE-273. Asheville, NC: U.S. Department of Agriculture, Forest Service, Southeastern Forest Experiment Station. 144 p.