Treesearch
Search National Treesearch
Displaying 15,691 - 15,700 of 17,624 Publications
- Measurements of the physical environment of urban open spaces in Syracuse, New York, were used to compute the physiological responses of human users of the spaces. These calculations were then used to determine what environmental variables were both important to human comfort and susceptible to control by site design. Although air temperature and humidity are important to human thermal comfort, these variables were found not to be related in any way to site features; temperature and humidity in the central business district were uniform over space. The other variables found to be important...AuthorsLee P. Herrington, J. S. VittumSourceIn: Heisler, Gordon M.; Herrington, Lee P., eds. Proceedings of the conference on metropolitan physical environment; Gen. Tech. Rep. NE-25. Upper Darby, PA: U.S. Department of Agriculture, Forest Service, Northeastern Forest Experiment Station. 130-138Year1977
- The thermal balance of a standard man was quantified for a variety of urban and rural summer daytime microclimates. The resulting net heat-load data were correlated with the relative amounts of vegetation and synthetic materials at each site. By extrapolating these results, it is possible to estimate the expected heat load of a proposed development before it is built.AuthorsThomas F. Stark, David R. MillerSourceIn: Heisler, Gordon M.; Herrington, Lee P., eds. Proceedings of the conference on metropolitan physical environment; Gen. Tech. Rep. NE-25. Upper Darby, PA: U.S. Department of Agriculture, Forest Service, Northeastern Forest Experiment Station. 139-151Year1977
- In urban and suburban areas of the United States (away from major airports), the outdoor noise environment usually depends strongly on local vehicular traffic. By relating traffic flow to population density, a model of outdoor noise exposure has been developed for estimating the cumulative 24-hour noise exposure based upon the population density of the area. This noise model has been used to provide first-order estimates of noise exposure in urban areas of this country. The model also can be used to estimate the variation in noise levels in communities and to plan community noise surveys....AuthorsDwight E. Bishop, Myles A. SimpsonSourceIn: Heisler, Gordon M.; Herrington, Lee P., eds. Proceedings of the conference on metropolitan physical environment; Gen. Tech. Rep. NE-25. Upper Darby, PA: U.S. Department of Agriculture, Forest Service, Northeastern Forest Experiment Station. 183-194Year1977
- Comparative measurements of exterior noise levels made at floors 3, 14, 26, and 37 of a high-rise apartment tower, when presented as a statistical distribution of percent exceedance vs. decibels, show the nature of the influence of local traffic at the low floors compared to the influence of an area source at the high floors. The open window penalty to interior noise levels was measured as well as the side street noise propagation along the building from avenue vehicular traffic sources alone.AuthorsNorman L. MeyersonSourceIn: Heisler, Gordon M.; Herrington, Lee P., eds. Proceedings of the conference on metropolitan physical environment; Gen. Tech. Rep. NE-25. Upper Darby, PA: U.S. Department of Agriculture, Forest Service, Northeastern Forest Experiment Station. 195-201Year1977
- This is a report on the Conference on Metropolitan Physical Environment, held in August 1975 at Syracuse, N.Y., where some 160 scientists and planners met to discuss the use of vegetation, space, and structures to improve the amenities for people who live in metropolitan areas.AuthorsGordon Heisler, Lee P. HerringtonSourceIn: Heisler, Gordon M.; Herrington, Lee P., eds. Proceedings of the conference on metropolitan physical environment; Gen. Tech. Rep. NE-25. Upper Darby, PA: U.S. Department of Agriculture, Forest Service, Northeastern Forest Experiment Station. 1-2Year1977
- Data collected on 26 July 1974 as a part of project METROMEX in St. Louis show the three-dimensional structure of the urban moisture field. Mesoscale dry regions at the urban surface, corresponding to large residential and light industrial land-use characterization, were responsible for a reduction in specific humidity in the urban mixing layer. Anthropogenic sources and sinks of water vapor were estimated and found to be insignificant for summer daytime mesoscale influences on the atmospheric water balance of the urban area. The effects of reduced moisture in the urban area are directly...AuthorsDouglas L. SistersonSourceIn: Heisler, Gordon M.; Herrington, Lee P., eds. Proceedings of the conference on metropolitan physical environment; Gen. Tech. Rep. NE-25. Upper Darby, PA: U.S. Department of Agriculture, Forest Service, Northeastern Forest Experiment Station. 26-35Year1977
- A heat and moisture excess over New York City is shown to exist by the analysis of helicopter soundings of temperature and wet-bulb depression. The magnitude of the temporal and spatial distribution of anthropogenic moisture emissions in New York City were estimated from fuel-usage data. The URBMET urban boundary-layer model was used to evaluate the effects on the dynamics of the urban boundary layer resulting from the observed urban moisture excess. Work is currently in progress to determine the fraction of the observed moisture excess over New York that is due to anthropogenic sources.AuthorsRobert D. Bornstein, Yam-Tong TamSourceIn: Heisler, Gordon M.; Herrington, Lee P., eds. Proceedings of the conference on metropolitan physical environment; Gen. Tech. Rep. NE-25. Upper Darby, PA: U.S. Department of Agriculture, Forest Service, Northeastern Forest Experiment Station. 36-52Year1977
- The broad features of urban climate anomalies are described and explained by combining recent METROMEX data with those from prior studies. The urban heat island is well understood, and urban effects upon cloud nuclei and cloud microstructure are clearly observed and explained in part; but the causes of urban effects upon rainfall remain speculative.AuthorsRoscoe R., Jr. BrahamSourceIn: Heisler, Gordon M.; Herrington, Lee P., eds. Proceedings of the conference on metropolitan physical environment; Gen. Tech. Rep. NE-25. Upper Darby, PA: U.S. Department of Agriculture, Forest Service, Northeastern Forest Experiment Station. 3-17Year1977
- Analyses of data from the first 4 years of a 5-year research project at St. Louis indicate a substantial enhancement of summer rainfall downwind of the urban-industrial complex. This anomaly appears to be caused primarily by the intensification of naturally occurring storm systems through the addition of heat and raindrop nuclei from the urban area. Most of the enhancement is associated with organized storm systems and is most pronounced during and after the period of maximum diurnal heating.AuthorsF. A. HuffSourceIn: Heisler, Gordon M.; Herrington, Lee P., eds. Proceedings of the conference on metropolitan physical environment; Gen. Tech. Rep. NE-25. Upper Darby, PA: U.S. Department of Agriculture, Forest Service, Northeastern Forest Experiment Station. 18-25Year1977
- The distribution of average rainwater pH over an area of 1,800 km² containing 81 collectors was determined from 25 storm events. The areal average of the data was pH 4.9, with a range of values from 4.3 to 6.8. A single storm event was studied to determine the change of pH as a function of time. The initial rain was pH 7.1, decreasing to 4.1. An excellent agreement was observed between the H+ deposition rate and the rainfall rate.AuthorsRichard G. SemoninSourceIn: Heisler, Gordon M.; Herrington, Lee P., eds. Proceedings of the conference on metropolitan physical environment; Gen. Tech. Rep. NE-25. Upper Darby, PA: U.S. Department of Agriculture, Forest Service, Northeastern Forest Experiment Station. 53-61Year1977